What was found
DURING TAXI OUT, ONCE ENG 2 WASTER SWITCH WAS ELEC TO ON ENG 1. FAIL ON ECAM CAME PROCEDURE WERE DONE ENG DAMAGE WAS SUSPECTED DUE TO EN NR 1 OIL PRESS AT 0 ENG 1. FIRE PUSH BUTTON WAS PUSHED. IAW TSM 72-00-00-810-806A WAS ACCOMPLISHED STEP 3A FADEC TES WITH ENG MOTORING & NON MOTORING WERE SATISFACTORY AMM 73-29-00-710-040 & CONTINUE WITH STEP 4B. CHECK THE CORRECT OPERATION OF THE LOW PRESS FUEL SHUT OFF SATISFACTORY AMM 28-24-00-720- 001. IAW TSM 72-00-00-810- 806-A WAS ACCOMPLISHED 4B TO 4BB NO DAMAGE FOUND. IAW TSM 72-00-00-810-806-A ITEM 4 B 4. BORESCOPE INSPECTION OF HIGH PRESS COMPRESSOR WAS PERFORMED. NO DAMAGE FOUND, NDT REPORT. P600816 SEE LOG PAGE P5474999-1 IAW SM 72-00-00-810-806-A. AITURE OF ENG 1 ITEM 4 B 4 WAS PERFORMED SEE NDT REPORTS GLL 0043-16GLL0044-16, GLL0046-16, GLL0047-16 & GLL0045-16 NO DISCREPANCIES WERE FOUND. IAW TSM 72-00-00-810-806-A ENG 1 ITEM 4 8 4 7 THE HMU WAS REPLACED. IAW AMM 71-00-00-710-003B ENG AUTOMATIC STAR WAS ACCOMPLISHED WITH RESULTS SATISFACTORINESS, THE FAULT ENG NR 1 FAILED DON'T SHOW ON ECAM.