Service difficulty report · Transducer · Airbus A318111

Difficulty date
January 17, 2019
Submitted
January 22, 2019
Operation
Air carrier
Aircraft
N592EL
Make and model
Airbus A318111
Aircraft serial
2358
Aircraft time
36,184 hours, 29,235 cycles
Part
Transducer
Condition
Out Of Adjust
Location
Bleed Air Sys
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

JAN 17. DURING DESCENT TO SKPS APU BLEED FAULT. CORRECTIVE ACTION: JAN 17. THIS ITEM IS DEFERRED TO DMI WO 2094888 IN ACCORDANCE WITH MEL 36-12-01 CAT C. CNMCC-2019-AV0280 // IN ACCORDANCE WITH TSM 49-00-81-810-860-A STEP 3.A. THE APU LAST LEG REPORT AND GROUND SCANNING SHOW INLET PRESS XDCR (8048KM) ASSOCIATED WITH FAULT CODE NUMBER (FCN) 22. PENDING CONTINUE TSM CHECK THE CONECTOR P22 // IN ACCORDANCE WITH T.S.M 49-00-081-860-A THE TRANSDUCER (8048KM) AND THEIR CONNECTOR WAS ADJUSTED AND CLEANED. OP TEST OF APU BLEED WAS PERFORMED SATISFACTORY