What was found
10.OCT.2021=> PIREP WO 16487931: DURING TO LEFT EMERGENCY EXIT (AFT) WAS PRESENTED ON ECAM TAKE OFF WAS REJECTED. PREVIOUS REPORTS INITIALLY CONSIDERED EXTERNAL EVENTS: 08.OCT.2021=> FL 8550AV PIREP WO 16487907: L DOOR EXIT OPEN APPEAR ON ECAM DURING APPROACH, DUE TO THE COVER THAT FELL OFF, THEN THE INDICATION DISSAPPEAR. 07.OCT.2021=> FL 9461AV PIREP WO 16487901: DURING T/O LEFT EMERGENCY EXIT DOOR APPEARED ON ECAM T/O WAS REJECTED (APPEARED OPEN). CORRRECTIVE ACTIONS / 10.OCT.2021 > IAW AMM 25-23-47-000-001-A/400-001-A THE COVER BRACKET WAS REPLACED AND SUBTASK 25-23-47-720-050-B TEST AMM 52-71-13-400-001- PROX SENSOR OFF THE DOOR WARNING SYSTEM HAS THE CORRECT TARGET WAS PERFORMED. CORRECTIVE ACTIOS TO PREVIOUS REPORTS: 08.OCT (WO 16487907) > SENSOR MONITORING FAULT AT THE LH PASSENGER COMPARTMENT EMERGENCY EXIT WAS PERFORMED TO STEP 3.B. IN ACCORDANCE WITH TSM 52-21-00-810-801-A. FUNCTIONAL CHECK OF THE COVER FLAP WAS SATISFACTORY 07.OCT (WO 16487901) > IAW AMM 52-21-11-400-001-A THE COVER ON EMERGENCY DOOR LF WAS INSTALLED CORRECTLY, TEST WAS SATISFACTORY.