What was found
PILOT REPORT 15.SEP.2022 WO 58'426'491=> DURING CLIMB AND DESEENT APU AUTO SHUT DOWN TWICE THIRD ATTEMPT ACCOMPLISHED SATISFACTORY.
ACTION TAKEN 15.SEP.2022 WO 58'426'491=> IN ACCORDANCE WITH AMM 49-94-14-04 CONF 16 AND 49-91-49-04 CONF 16, REV. 61, THE VALVE - SOLENOID, DE-OILING AND PRESSURE SWITCH - OIL WERE REPLACED AND OPERATIONAL TEST OF APU WAS PERFORMED. TEST SATISFACTORY.