What was found
DURING SCHEDULE MAINTENANCE WALL SUPPORT FS 281 BL 22L HAS CORROSION BEYOND LIMITS. INSTALLED FLOORBEAM REPAIR AT FS 281 BL22L IAW SRM 53-21-00 FIG 815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULE MAINTENANCE WALL SUPPORT FS 281 BL 22L HAS CORROSION BEYOND LIMITS. INSTALLED FLOORBEAM REPAIR AT FS 281 BL22L IAW SRM 53-21-00 FIG 815.