What was found
DURING SCHEDULE MAINTENANCE FLOORBEAM AT FS 237 HAS EVIDENCE OF CORROSION UNDER MOON COVER. REMOVED TO EVALUATE. REMOVED CORROSION AT FS 237 IAW SRM 51-21-01 FOUND OUT OF LIMITS IAW SRM 51-21-01. INSTALLED FLOORBEAM REPAIRED IAW SRM 53-21-00 FIG 815.