Service difficulty report · Line · Doug DC862

Difficulty date
March 24, 2002
Submitted
April 2, 2002
Operation
Air carrier
Aircraft
N8969U
Make and model
Doug DC862
Aircraft serial
46070
Aircraft time
66,880 hours, 18,856 cycles
Part
Line
Condition
Leaking
Location
Pt 2
Stage of operation
CL
How discovered
O
Nature of condition
R, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMBOUT NR 1 ENGINE FAILED TO PRODUCE APPROPRIATE POWER ALL OTHER ENGINE PARAMETERS NORMAL, PROCEEDED WITH ABNORMAL CHECKLIST AND LANDED WITH NO FURTHER INCIDENTS. PREFORMED EPR CHECK IAW MM 77-11-0, FOUND PT-2 LINE OBSTRUCTED AT INLET GUIDE VANE CASE. PERFORMED ENGINE RUN-UP IAW MM 71-00, ALL OTHER PARAMETERS CHECKED NORMAL. TRANSFERRED EPR INDICATION TO DMI 16369 PER MEL 77-1-2. CHECKED NR 1 ENGINE EPR. LINES FOR LEAK; FOUND PT2 LINE LEAKING. REMOVED AND REPLACED PT2 RIGID LINE IAW MM 70-30-3 & MM 70-11-0. PERFORMED ENGINE RUN-UP, TAKE OFF POWER FOUND NORMAL IAW DC8 MM 71-00 CLEARED DMI 16369.