What was found
DURING POST FLIGHT INSPECTION THE FOLLOWING WAS FOUND: NR 3, 4 & 8 MWA THERMAL FUSE MELTED; NR 7 MWA DUE CHANGE FROM STRESS BEYOND LIMITS. FOUND CRACK AT NR 3 & 4 BRAKE ASSY. DURING MWA; FOUND NR 8 BRAKE ASSY. SEVERLY OVERHEATED AT MWA. FOUND NR 7 & 6 BRAKE NOT OPERATING. REMOVED AND REPLACED NR 3, 4 AND 8 MWA IAW DC8 MM 32-40-1. REMOVED AND REPLACED NR 7 MWA IAW DC8 MM 32-40-1. REMOVED AND REPLACED NR 3, 4 AND 8 BRAKE ASSY. IAW DC8 MM 32-42-1. REMOVED AND REPLACED RH OUTBD ANTISKID VALUE IAW MM 32-43-3 LEAK CHECK OK OPS CHECK OK IAW DC8 MM 32-43-0. REMOVED AND REPLACED ANTISKID CONTROL BOX IAW MM 32-43-0. ACCOMPLISHED COMPLETE ANTISKID TEST OK IAW 32-43-0