What was found
DURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 440 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 440 IAW STC SA1063SO AND SA1377SO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 440 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 440 IAW STC SA1063SO AND SA1377SO.