What was found
DURING (C) CHECK INSPECTION THE FOLLOWING WAS FOUND; STATION 1766 AFT PRESSURE BULKHEAD, L-3R UUPER EAP WITH 2 INCH CRACK. TRIMMED OUT DAMAGED AREA AND FABRICATED REPAIR PART IAW REPAIR ORDER AROW-031RO-2, PAGE 1 TO 2, DATED 05/01/03 AND REPAIR DRAWING NUMBER AIPSAC-N784AL-02/03, SHEET 1 TO 5, REV.IR, DATED 05/01/03. TREATED AND PRIMED REPAIR PARTS IAW DC8 SRM 51-1-8 AND INSTALLED REPAIR PARTS IAW REPAIR ORDER AROW-031RO-2, PAGE 1 AND 2, DATED 05/01/03 AND DRAWING NR AIPSAC-N784AL-02/03. ISSUED FAA FORM 8110-3. NO LEAKS WERE NOTED IAW MM 21-31-0.