What was found
DURING ROUTINE INSPECTION THE FOLLOWING WAS FOUND; AFT ENTRANCE DOOR JAMB AFT BOTTOM CORNER WITH CRACKS OF 0.625 & 0.437 INCH. REPAIRED THE AFT ENTRANCE DOOR JAMB AFT BOTTOM CORNER IAW SRM 53-2-0 FIG 18, SHEETS 1, 5, 6, 7 & 8, TEMPORARY REVISION 53-134 & TEMPORARY REVISION 53-158, DATED 01/23/02 & 12/20/02 RESPECTIVELY EA 1020, DATED 08/21/03.