What was found
DURING "C" CHECK INSPECTION, THE FOLLOWING WAS FOUND LT HORIZONTAL STABILIZER XH 285.00 L/E LOWER SURFACE WITH DENT. REPAIRED L/E PLATING OF LT HORIZONTAL STABILIZER BETWEEN XFS 263 AND XH 285 IN ACCORDANCE WITH AIPSAC DRAWING NR AIPSAC-N661AVE-03/07, SHEET 1 TO 4, DRAWING DATE 01/08/2007.