What was found
DURING C-CHECK INSPECTION, FOUND BROKEN FRAME AT RT MLG WHEEL WELL INNER SECTION. REPAIRED SECTION AT RT MAIN GEAR IAW DC8 SRM 53-2-1, FIG 1B SH 3. TREATED AND INSTALLED ANGLE DOUBLER IAW DC8 SRM 51-1-8, 51-1-21, CF W/O 017402 N/R 0229.