What was found
DURING C-CHECK, FOUND CORRODED INTERCOASTAL UPPER FITTING AT NR 3 PIT DOOR STA 1220. REMOVED AND REPLACED CORRODED INTERCOASTAL UPPER FITTING AT NR 3 PIT DOOR IAW DC-8 SRM 51-1-21 AND 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND CORRODED INTERCOASTAL UPPER FITTING AT NR 3 PIT DOOR STA 1220. REMOVED AND REPLACED CORRODED INTERCOASTAL UPPER FITTING AT NR 3 PIT DOOR IAW DC-8 SRM 51-1-21 AND 51-3-0.