What was found
DURING INSPECTION, FOUND FWD AND AFT MAIN LANDING GEAR DOORS HINGE SUPPORTS CRACKED. FOUND NR 2, 7, 8, 9 TEE SUPPORTS CRACKED. REMOVED CRACKED SUPPORTS, CLEANED, TREATED AND PRIMED AREA. FABRICATED AND INSTALLED NEW SUPPORTS IAW DACO FAX ACTION NR 33065.