What was found
DURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 1260, LONG 21L, FRAME ATTACH FITTING HAS CORROSION (FWD SIDE). REMOVED CORROSION AND FOUND BEYOND LIMITS I/A/W 51-1-8, FABRICATED FITTING I/A/W DAC AUTHORIZATION NR CI-P63-ATM-560 AND DAC ACTION 342952 WO 970035 N/R 5014. INSTALLED FITTING I/A/W 51-1-20D AND 51-3-0.