What was found
DURING CPCP INITIAL INSPECTION, FOUND MAIN CARGO CABIN UNDERNEATH NR 4 CENTER FLOOR PANEL, METAL STRIP ON FLOOR SUPPORT STA 100 SURFACE CORRODED LEVEL 1. REMOVED CORROSION, FOUND TO BE BEYOND LIMITS IAW 51-1-8, FABRICATED PARTS I/A/W DER APPROVED DRWG NR 97090404. INSTALLED REPAIR IAW DER DRAWING, WO 970035 N/R 5067.