What was found
DURING D-CHECK, FOUND MAIN CABIN FLOORBEAM AT FS 260 LEFT HAND HAS CORROSION. CUT OUT DAMAGED AREA. FABRICATED FILLER AND REPAIR ANGLE AND INSTALLED IN ACCORDANCE WITH AVITAS ENGINEERING, EO 98AROW.021D-3128. WORK ACCOMPLISHED UNDER ARROW AIR FORM JW3B, WORK ORDER, 970101, ITEM NR 3128, CONTROL NR 5162A.