What was found
LT MLG W/W LEVEL 1 CORROSION IN FWD LT UPPER ANGLE SHIM FUS STA 857.000. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC-8 SRM 53-2-0. REMOVED CORRODED SHIM CLEANED SURROUNDING AREA WITHIN LIMITS IAW DC-8 SRM 53-2-0. FABRICATED NEW SHIM IAW DC-8 SRM 51-1-4. TREATED PRIMED AND INSTALLED NEW SHIM IAW DC-8 SRM 51-1-8, 51-1-20D. REF SEE CF WORK ORDER 020663 NR CONTROL NR 5210.