What was found
C-CHECK, 4.5 INCH CRACK IN LONGERON SPLICE FITTING 25R STA 1090. REPLACED LONGERON FITTING PER SRM 51-1-20 UNDER WORK ORDER NR 1302.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C-CHECK, 4.5 INCH CRACK IN LONGERON SPLICE FITTING 25R STA 1090. REPLACED LONGERON FITTING PER SRM 51-1-20 UNDER WORK ORDER NR 1302.