As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR PANEL SUPPORT ANGLE AT FS 225R TO FS 273R CORRODED AT FLOOR LEVEL. CUT OUT CORRODED AREA. FABRICATED AND INSTALLED 2024.T3 .063 INCH FILLER AND 2024.T3 .071 INCH DOUBLER IAW MHA ENG. INC., E. O. MHA-3065 UNDER AMRC W. O. 960165. (X)