PAE - FOUND CORROSION AFT CARGO BAY ON FLOOR SUPPORTS AT PREVIOUS REPAIR. BLENDED CORROSION ON FLOOR SUPPORTS, FOUND SEVERAL LOCATIONS OUT OF LIMITS, GENERATED MIG-5'S TO DOCUMENT INDIVIDUAL REPAIRS. (M)