What was found
DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE FROM FORWARD GALLEY TO ROW 2. REPAIRED BROKEN WIRES, REPLACED LIGHT SECTION, OPS CHECKED NORMAL RELEASED FOR SERVICE (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.