What was found
OKC - FOUND DURING 30K CHECK, JACKSCREW ACCESS PANEL ON THE VERTICAL STABILIZER HAS CHAFED FRAME MATING FACE. REPLACED FRAME PER SRM 51-30-2 AND 51-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - FOUND DURING 30K CHECK, JACKSCREW ACCESS PANEL ON THE VERTICAL STABILIZER HAS CHAFED FRAME MATING FACE. REPLACED FRAME PER SRM 51-30-2 AND 51-30-5. (M)