What was found
OKC - FOUND DURING 30K CHECK, RIGHT AILERON HINGE PANEL NR 3 IS CRACKED AT DRAIN HOLE. STOP DRILLED CRACK AND VERIFIED CONTAINMENT BY EDDY CURRENT INSPECTION PER SRM 51-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - FOUND DURING 30K CHECK, RIGHT AILERON HINGE PANEL NR 3 IS CRACKED AT DRAIN HOLE. STOP DRILLED CRACK AND VERIFIED CONTAINMENT BY EDDY CURRENT INSPECTION PER SRM 51-01. (M)