What was found
OKC - DURING 30K CHECK, FOUND MID CARGO BAY FLOOR PANEL IS GOUGED IN SEVERAL PLACES ALONG EDGE. REPLACED PANEL PER SRM 51-10-2 AND 10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - DURING 30K CHECK, FOUND MID CARGO BAY FLOOR PANEL IS GOUGED IN SEVERAL PLACES ALONG EDGE. REPLACED PANEL PER SRM 51-10-2 AND 10-4. (M)