What was found
OKC - FOUND DURING 30K CHECK, FORWARD CENTER FLOOR PANEL MOUNTING SUPPORT IS CORRODED AT FS 200. REPLACED SUPPORT PER SRM 51-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - FOUND DURING 30K CHECK, FORWARD CENTER FLOOR PANEL MOUNTING SUPPORT IS CORRODED AT FS 200. REPLACED SUPPORT PER SRM 51-30-5. (M)