What was found
OAK - DUIRNG C-CHECK, FOUND FLOORBEAM CORRODED ON OUTBOARD OF PANEL F-6, FS 160-196. REPLACED SUPPORT BEAM PER SRM 51-10-4 AND 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OAK - DUIRNG C-CHECK, FOUND FLOORBEAM CORRODED ON OUTBOARD OF PANEL F-6, FS 160-196. REPLACED SUPPORT BEAM PER SRM 51-10-4 AND 51-30-2. (M)