What was found
OKC - DURING 15K CHECK, FOUND FUSELAGE SKIN CORRODED AT STATION 769 TO 788 UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. INSTALLED DOUBLER, FILLERS, ANGLE, SHIMS, TRIPLER, AND SPLICE PER EA 5330-01708. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - DURING 15K CHECK, FOUND FUSELAGE SKIN CORRODED AT STATION 769 TO 788 UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. INSTALLED DOUBLER, FILLERS, ANGLE, SHIMS, TRIPLER, AND SPLICE PER EA 5330-01708. (M)