As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GYR - FOUND STATION 360 RBL 39 TO RBL 55 FLOORBEAM HAS CORROSION TOP AND BOTTOM AROUND SCREW HOLES, GALLEY AND SEAT TRACK FITTINGS. REMOVED CORROSION AND CHECKED LIMITS AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-51. FABRICATED 2 AND 3 AND FILLER PARTS PER SRM 53-30-51 AT STATION 360, RBL 89 TO RBL 55. (M)