What was found
PAE - FOUND SCRATCH DAMAGE JUST AFT OF AFT LAVATORY SERVICE PANEL, SCRATCHES WERE BLENDED AND FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-01. REPAIRED SCRATCH/GOUGE AT STAITON 1006/STRINER 25R. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - FOUND SCRATCH DAMAGE JUST AFT OF AFT LAVATORY SERVICE PANEL, SCRATCHES WERE BLENDED AND FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-01. REPAIRED SCRATCH/GOUGE AT STAITON 1006/STRINER 25R. (M)