What was found
OKC - DURING INSPECTION, FOUND AFT PIT STATION 1193 BETWEEN STRINGER 20 AND 29L SHEAR TIE CORRODED. REPAIRED BY REMOVED DAMAGE, FABRICATED REPAIR SHEAR TIE AND SPLICE IAW MD80 SRM 53-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - DURING INSPECTION, FOUND AFT PIT STATION 1193 BETWEEN STRINGER 20 AND 29L SHEAR TIE CORRODED. REPAIRED BY REMOVED DAMAGE, FABRICATED REPAIR SHEAR TIE AND SPLICE IAW MD80 SRM 53-03. (M)