DURING INSPECTION, FOUND AFT PIT LOWER FLANGE ON BEAM AT CARGO DOOR IS CORRODED AT STATION 1182. REPAIRED BY REMOVED DAMAGED BEAM, INSTALLED NEW BEAM IAW MD80 SRM 51-30-2, 51-30-5, 51-10-3. (M)