What was found
OKC - DURING HV CHECK, FOUND FRAME FASTENER HOLE IS WORN OUT OF ROUND AT FS 1322. REMOVED DAMAGE. INSTALLED REPAIR ANGLE, FILLER, AND SHIM PER SRM 53-05. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - DURING HV CHECK, FOUND FRAME FASTENER HOLE IS WORN OUT OF ROUND AT FS 1322. REMOVED DAMAGE. INSTALLED REPAIR ANGLE, FILLER, AND SHIM PER SRM 53-05. (M)