What was found
DURING HV CHECK, FOUND CABIN FLOOR PANEL FROM STATION 886 TO STATION 946 IS CHAFED AND CRACKED. REMOVED DAMAGED W CHANNEL, ORDERED AND INSTALLED NEW W CHANNEL IAW MD80 SRM 51-30-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HV CHECK, FOUND CABIN FLOOR PANEL FROM STATION 886 TO STATION 946 IS CHAFED AND CRACKED. REMOVED DAMAGED W CHANNEL, ORDERED AND INSTALLED NEW W CHANNEL IAW MD80 SRM 51-30-8. (M)