What was found
PAE - AFT CARGO BAY FLOORBOARD NR 4 GOUGED AT RT FORWARD TIE DOWN CUTOUT. REMOVED GOUGED BY .25 INCH BY 1 INCH, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53 FIG 101 DETAIL V. FABRICATED, ALODINED AND PRIMED ACB NR 4 FLOORBOARD IAW 51-40-2 STEP 8B AND AMM 51-21-21 STEP 3 MADE OUT OF 2024 T3 .071 INCH LOT 586654 IAW SRM 53-60-95 FIG 1, SH 4, DETAIL NR. (M)