What was found
OKC - FOUND STRINGER 17 CREASE BEAM HAS SHORT EDGE DISTANCE FROM PREVIOUS REPAIR. REMOVED DAMAGED SECTION OF CREASE BEAM AND INSTALLED NEW SECTION OF CREASE BEAM IAW B737-400 SRM 53-00-01 FIG 201 AND SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - FOUND STRINGER 17 CREASE BEAM HAS SHORT EDGE DISTANCE FROM PREVIOUS REPAIR. REMOVED DAMAGED SECTION OF CREASE BEAM AND INSTALLED NEW SECTION OF CREASE BEAM IAW B737-400 SRM 53-00-01 FIG 201 AND SRM 51-40-02. (M)