What was found
OKC - FOUND CORROSION ON FLOORBEAM AT BS 344 UPPER FLANGE. REMOVED DAMAGE, CORROSION, FABRICATED AND INSTALLED REPLACEMENT UPPER CHORD IAW ASA EA 5320-01710. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OKC - FOUND CORROSION ON FLOORBEAM AT BS 344 UPPER FLANGE. REMOVED DAMAGE, CORROSION, FABRICATED AND INSTALLED REPLACEMENT UPPER CHORD IAW ASA EA 5320-01710. (M)