FOUND CORRODED MOPSILL AT AFT ENTRY DOOR. BLENDED CORROSION ON MOPSILL OUT OF LIMITS. REMOVED AND REPLACED MOPSILL PER SRM 51 40 02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORRODED MOPSILL AT AFT ENTRY DOOR. BLENDED CORROSION ON MOPSILL OUT OF LIMITS. REMOVED AND REPLACED MOPSILL PER SRM 51 40 02.