What was found
NUMBER 2 SLAT IS BULGED AND DELAMINATED AT TRAILING EDGE INBOARD CORNER. PREPPED DELAMINATED AREA, FABRICATED AND INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 2 SLAT IS BULGED AND DELAMINATED AT TRAILING EDGE INBOARD CORNER. PREPPED DELAMINATED AREA, FABRICATED AND INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-70-10.