What was found
FLOORBEAM STA 967 IS CORRODED BETWEEN LBL 30 AND RBL 30 UPPER CHORD. REMOVED CORRODED SECTION OF FLOORBEAM UPPER CHORD. FABRICATED AND INSTALLED REPAIR CHORD ANGLES AND STRAPS IAW SRM 53-00-51 FIG 201 REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.