What was found
RT WING T/E AFT OB FLAP, 3 EACH DENTS CLOSE TOGETHER 5 TO 2 INCHES FROM T/E AND 21 INCHES FROM IB END. PREPARED DAMAGED AREA FABRICATED REPAIR DOUBLER AND BONDED IAW SRM 51-70-10, REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING T/E AFT OB FLAP, 3 EACH DENTS CLOSE TOGETHER 5 TO 2 INCHES FROM T/E AND 21 INCHES FROM IB END. PREPARED DAMAGED AREA FABRICATED REPAIR DOUBLER AND BONDED IAW SRM 51-70-10, REPAIR 2.