What was found
FWD CARGO DOOR CUTOUT THRESHOLD WEB CORRODED ON LWR SIDE AROUND NUT PLATES STA 447 TO STA 485 RBL 30 TO RBL 32 WL 156. REMOVED DAMAGED THRESHOLD WEB LOCATED DRILLED AND INSTALLED A REPLACEMENT WEB IAW SRM 51-40-02 FIG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO DOOR CUTOUT THRESHOLD WEB CORRODED ON LWR SIDE AROUND NUT PLATES STA 447 TO STA 485 RBL 30 TO RBL 32 WL 156. REMOVED DAMAGED THRESHOLD WEB LOCATED DRILLED AND INSTALLED A REPLACEMENT WEB IAW SRM 51-40-02 FIG 9.