What was found
R1 DOOR THRESHOLD WEB CORRODED BETWEEN STA 298 TO 328 AREA. REMOVED DAMAGED WEB, FABRICATED LOCATED DRILLED AND INSTALLED NEW WEB IAW B737 400 SRM 51 30 01 PG 7 AND 51 40 02 PAGES 2 AND 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR THRESHOLD WEB CORRODED BETWEEN STA 298 TO 328 AREA. REMOVED DAMAGED WEB, FABRICATED LOCATED DRILLED AND INSTALLED NEW WEB IAW B737 400 SRM 51 30 01 PG 7 AND 51 40 02 PAGES 2 AND 4.