Service difficulty report · Valve · Boeing 737890

Difficulty date
June 12, 2008
Submitted
July 1, 2008
Operation
Air carrier
Aircraft
N587AS
Make and model
Boeing 737890
Aircraft serial
35684
Aircraft time
3,474 hours, 737 cycles
Part
Valve
Part number
3989083
Part serial
9965
Condition
Faulted
Location
Cabin Temp
Part time
2,474 hours, 737 cycles
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

UNABLE TO ADJUST FWD OR AFT CABIN TEMP USING CONTROL KNOBS. CONT CABIN WORKS NORMAL. POSTIONED TRIM AIR SWITCH TO OFF POSITION ABLE TO CONTROL CABIN TEMPS. TEMP CONTROLLER (ZONE 2): FAULTED THE TRIM AIR MOD VALVE FOR THE FWD PASS CABIN. REMOVED AND REPLACED MOD VALVE PER: M M21 61 21. TEMP CONTROLLER FAULTS CLEARED (CONFIRM FIX).