What was found
FOLLOW UP TO FREQUENT NR 2 IDG SERVICING WITH REPORT OF OIL STREAKS. ACCOMPLISH IDG STATIC LEAK CHECK REF AMM 24 11 00 700 801. ACCOMP TSR NO LEAKS FOUND DURING IDLE RUN. REMOVED & REPLACED NR 2 ENG IDG REF MM 24 11 11 LEAK & OPS NORMAL REF MM 24 11 00. P/N VERIFICATION REF IPC 24 11 11 50, GRND VERIFICATION GOOD.