What was found
WHILE ACCOMPLISHING OPS CHECK OF NR 2 ENGINE AFTER ENGINE CHANGE NOTED ENGINE DRIVEN PUMP WILL NOT SHUT OFF CLEANED CONNECTOR PER SWPM 20-60-01. OPS CK GOOD. VERIFIED HYD PUMP SHUTS OFF DURING GROUND RUN REF AMM 29-11-11-710-015-002.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE ACCOMPLISHING OPS CHECK OF NR 2 ENGINE AFTER ENGINE CHANGE NOTED ENGINE DRIVEN PUMP WILL NOT SHUT OFF CLEANED CONNECTOR PER SWPM 20-60-01. OPS CK GOOD. VERIFIED HYD PUMP SHUTS OFF DURING GROUND RUN REF AMM 29-11-11-710-015-002.