What was found
AFT CARGO PIT FLOOR PANEL T-SPLICE STRAP AT BS 767+6 RBL 20 TO LBL 20 HAS CORROSION. T-SPLICE STRAP CORROSION BLENDED OUT. BLEND AREA FOUND TO BE BEYOND LIMIT. NEW REPAIR STRAP MADE IAW B737 700 SRM 53 00 53 AND 53 60 53.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO PIT FLOOR PANEL T-SPLICE STRAP AT BS 767+6 RBL 20 TO LBL 20 HAS CORROSION. T-SPLICE STRAP CORROSION BLENDED OUT. BLEND AREA FOUND TO BE BEYOND LIMIT. NEW REPAIR STRAP MADE IAW B737 700 SRM 53 00 53 AND 53 60 53.