As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO PIT FLOOR PANEL AT BS 767 TO 887 HAS CORROSION ON UPPER EDGES AND NUMEROUS GOUGES ON THE SIDE. AFT CARGO PIT FLOOR PANEL AT BS 767 TO 887 CORROSION BLENDED OUT. BLEND AREA FOUND TO BE WITHIN ALLOWABLE DAMAGE LIMIT AND GOUGES FOUND TO BE BEYOND LIMITS. FLOOR PANEL REPLACED IAW B737 700 SRM 51 40 05.