What was found
FWD CARGO PIT LT FLOOR TO SIDEWALL ZEE ANGLE CORRODED STA 500 F + 10" TO 500 L LBL 23. CUT OUT DAMAGED SECTION, FABRICATED, LOCATED, DRILLED AND INSTALLED A REPLACEMENT SECTION IAW B737 900 SRM 53 00 53 FIG 201 202 REPAIR 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT LT FLOOR TO SIDEWALL ZEE ANGLE CORRODED STA 500 F + 10" TO 500 L LBL 23. CUT OUT DAMAGED SECTION, FABRICATED, LOCATED, DRILLED AND INSTALLED A REPLACEMENT SECTION IAW B737 900 SRM 53 00 53 FIG 201 202 REPAIR 5.